2P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP44 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP44 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP44 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP44 | ||
3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP44 | ||
3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
75 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP44 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP67 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP67 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP67 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP67 | ||
3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 3P+N+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP67 | ||





3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 3P+N+E | ||
| Dimension (mm) |
a |
76 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP67 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 63A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
axb |
105 |
|
| Cable nominal cross-section area(mm2) | 6-16 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP67 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 125A | |||
| No.poles | 2P+E | ||
| Dimension (mm) |
axb |
120 |
|
| Cable nominal cross-section area(mm2) | 16-50 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | IP67 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 63A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
105 |
|
| Cable nominal cross-section area(mm2) | 6-16 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP67 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 125A | |||
| No.poles | 3P+E | ||
| Dimension (mm) |
axb |
120 |
|
| Cable nominal cross-section area(mm2) | 16-50 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | IP67 | ||





3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 63A | |||
| No.poles | 3P+N+E | ||
| Dimension (mm) |
axb |
105 |
|
| Cable nominal cross-section area(mm2) | 6-16 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP67 | ||
3P+N+E
| Earth contact position Normal current(A) |
6h | ||
| 125A | |||
| No.poles | 3P+N+E | ||
| Dimension (mm) |
axb |
120 |
|
| Cable nominal cross-section area(mm2) | 16-50 | ||
| Voltage(V) | 200-346V~/240-415V~ | ||
| Protection degree | IP67 | ||
2P+E
| Earth contact position Normal current(A) |
4h | ||
| 16A | |||
| No.poles | 2P+E | ||
|
Dimension |
a b c φ |
122 59 51 6 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 110-130V~ | ||
| Protection degree | IP44 | ||





2P+E
| Earth contact position Normal current(A) |
4h | ||
| 32A | |||
| No.poles | 2P+E | ||
| Dimension (mm) | a b c φ |
139 75 64 8 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 110-130V~ | ||
| Protection degree | IP44 | ||





2P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 2P+E | ||
| Dimension (mm) | a b c φ |
122 59 51 6 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | lP44 | ||
2P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 2P+E | ||
| Dimension (mm) | a b c φ |
139 75 64 8 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 200-250V~ | ||
| Protection degree | lP44 | ||





3P+E
| Earth contact position Normal current(A) |
6h | ||
| 16A | |||
| No.poles | 3P+E | ||
| Dimension (mm) | a b c φ |
122 65 51 6 |
|
| Cable nominal cross-section area(mm2) | 1-2.5 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | lP44 | ||
3P+E
| Earth contact position Normal current(A) |
6h | ||
| 32A | |||
| No.poles | 3P+E | ||
| Dimension (mm) | a b c φ |
139 75 64 8 |
|
| Cable nominal cross-section area(mm2) | 2.5-6 | ||
| Voltage(V) | 380-415V~ | ||
| Protection degree | lP44 | ||